The AHBLG-500 square cross flow cooling tower represents our flagship GRP solution for overseas buyers requiring reliable heat rejection in continuous-duty applications such as petrochemical processing, food cold storage, and data center cooling systems. Manufactured under ISO standards, this export-grade unit combines a heavy-duty steel framework with UV-stabilized FRP panels, oversized drift eliminators, and maintenance-friendly access platforms. As a direct-from-factory exporter, we provide complete documentation including performance curves, NCPI compliance, and spare parts lists, ensuring seamless integration into your existing water circulation network while reducing total ownership cost through our volume-driven pricing and dedicated after-sales technical support.
Hebei Fortis Technology Co., Ltd Product Brochure
Product Advantages
Superior Corrosion Resistance for Harsh Environments
The AHBLG-500 is constructed with high-grade, UV-stabilized glass-reinforced plastic (GRP) panels and a hot-dip galvanized steel frame, offering exceptional resistance to rust, chemical exposure, and saline air. Unlike traditional metal towers that degrade within 3–5 years in industrial or coastal settings, this GRP structure maintains its structural integrity for over a decade, drastically reducing maintenance downtime and replacement costs for your plant operations.
Energy-Efficient Cross-Flow Design with Lower Pumping Head
Our square cross-flow configuration allows gravity-driven water distribution over the fill media, which requires a significantly lower pumping head compared to counter-flow designs. This translates into 15–20% less energy consumption on your circulation pump motor, directly cutting your monthly electricity bills. The large, clog-resistant nozzle system also ensures uniform water coverage, maximizing heat transfer efficiency even with variable water flow rates.
Quiet Operation Ideal for Urban or Noise-Sensitive Sites
The AHBLG-500 features low-speed centrifugal fans and advanced drift eliminators that minimize both mechanical noise and water splash sounds. With sound pressure levels kept below 62 dB(A) at 15 meters, this tower is perfectly suited for installation near office complexes, hospitals, or residential areas—common pain points for factory expansion projects that face local noise compliance regulations.
Parameter Specifications
|
|
||||||||||
|
Product |
Square Cross Flow Cooling Tower |
|||||||||
|
Model |
τ=28℃ |
Main Dimensions (mm) |
Air Volume m³/h |
Fan Diameter (mm) |
Motor Installed Capacity (kw) |
Weight (t) |
τ=28℃ |
Noise at standard point |
||
|
Total Height |
Length× |
self-weight |
operating weight |
|||||||
|
AHBLD/HBLD-300 |
300 |
4514 |
7250× 3810 |
167000 |
3400 |
7.5 |
5.85 |
13.38 |
/ |
59.0 |
|
AHBLD/HBLD-500 |
500 |
5230 |
8033× 4650 |
260000 |
4200 |
11.0 |
9.2 |
17.24 |
/ |
61.5 |
|
AHBLD/HBLD-700 |
700 |
5319 |
8930× 6640 |
370000 |
5000 |
18.5 |
12.95 |
26.05 |
/ |
62.6 |
|
AHBLCD/HBLCD-300 |
300 |
6230 |
10650× 3810 |
167000 |
3400 |
7.5 |
7.05 |
14.18 |
/ |
52.5 |
|
AHBLCD/HBLCD-500 |
500 |
7030 |
11640× 4650 |
260000 |
4200 |
11.0 |
10.8 |
18.84 |
/ |
53.7 |
|
AHBLCD/HBLCD-700 |
700 |
7180 |
12540× 6640 |
370000 |
5000 |
18.5 |
14.75 |
26.81 |
/ |
54.5 |
|
AHBLG/HBLG-300 |
/ |
4514 |
7250× 3810 |
200000 |
3400 |
11.0 |
6.13 |
13.66 |
300 |
64.5 |
|
AHBLG/HBLG-500 |
/ |
5230 |
8033× 4650 |
320000 |
4200 |
18.5 |
9.42 |
17.46 |
500 |
65.0 |
|
AHBLG/HBLG-700 |
/ |
5319 |
8930× 6640 |
450000 |
5000 |
30.0 |
13.19 |
26.29 |
700 |
66.0 |
|
The standard point noise is measured at a distance equal to the equivalent diameter of the air inlet window or its shield equivalent diameter, and 1.5 meters above the ground. The equivalent diameter Dₘis calculated by the formula: Dₘ= 1.13×Length×Width |
||||||||||
|
Features |
The FRP cooling tower serves not only as a temperature regulator but also delivers an efficient, durable, and maintenance-free solution with optimized lifecycle costs. By harnessing the unique properties of FRP materials, it fundamentally addresses the critical challenges of corrosion and lifespan limitations in harsh operating environments, making it the go-to choice for cooling systems in modern industrial and commercial facilities. |
|||||||||
|
Application
|
Central air conditioning system: refrigeration station for commercial buildings, hotels and hospitals. |
|||||||||
|
Industrial refrigeration: process cooling for food processing, chemical, pharmaceutical and plastic industries. |
||||||||||
|
Power industry: auxiliary cooling system for thermal power plant and nuclear power plant. |
||||||||||
|
Manufacturing industry: circulating water cooling for metallurgical and mechanical processing plants. |
||||||||||
|
Data center: Provides cooling water for server rooms. |
||||||||||
|
Payment |
T/T, Western Union. |
|||||||||
|
Service |
Customize and design the size and style according to requirements |
|||||||||