The DBNL3J-100 is a collecting-type counterflow FRP cooling tower that operates at just 55 dB(A) at 10 meters, making it a preferred choice for urban commercial projects and factory workshop roof installations where acoustic compliance is mandatory. Its integrated basin not only simplifies field installation but also prevents water splashing loss, improving overall thermal efficiency by up to 8% over non-collecting designs. We manufacture this model with flame-retardant FRP panels and heavy-duty gearboxes rated for 80,000-hour continuous duty. As an end-user focused exporter, we avoid generic stock units—instead, we configure each tower’s fill depth, nozzle pressure, and motor HP to match your local summer design wet-bulb temperature. Our after-sales support includes remote commissioning via video guidance and emergency spare parts airfreight within 48 hours. For buyers prioritizing total cost of ownership over upfront price, we offer 5-year warranty on FRP shell and 2-year warranty on mechanical drivetrain, backed by our wholly-owned service team in key port cities.
Hebei Fortis Technology Co., Ltd Product Brochure
Product Advantages
Acoustic Performance That Meets Urban Planning Restrictions
The DBNL3J-100 is engineered with a low-speed fan configuration and a specially staggered fill arrangement that disrupts water falling noise at its source. Unlike standard towers that simply add silencers as an afterthought, we optimize the blade tip speed and water droplet trajectory from the design phase. This results in a measured noise level of ≤55 dB(A) at 15 meters during full-load operation—well below the 60 dB(A) threshold required by most residential-commercial mixed-use zones. For projects facing nighttime operation curfews, we can further supply an optional variable-frequency drive (VFD) that reduces fan speed by 30% during off-peak hours, cutting noise to just 49 dB(A) without triggering thermal performance alarms.
Integral Collecting Basin That Eliminates Field Fabrication Risks
The built-in cold-water collection basin is not an add-on accessory but a structural part of the tower’s lower casing, manufactured as a single-piece FRP molding with no seam leakage points. This design delivers two critical benefits: firstly, it removes the need for onsite concrete sump construction, which typically consumes 5–7 working days and invites waterproofing failures; secondly, the basin’s built-in anti-vortex baffles and pre-filtration screen ensure that pump suction pressure remains stable even when water level fluctuates within ±50mm. For site managers, this means faster installation, reduced civil works cost, and zero post-commissioning leakage callbacks—a tangible saving of roughly 12–15% of total project installation budget.
Counterflow Thermal Gradient That Outperforms Crossflow in Variable Loads
While crossflow towers dominate low-cost markets, the counterflow design of the DBNL3J-100 places the hottest incoming water (up to 45°C) in direct contact with the coldest, driest air at the bottom fill layer. This counter-current exchange creates a true logarithmic mean temperature difference (LMTD) that is 18–22% more efficient than equivalent crossflow models when cooling load fluctuates between 60% and 100% capacity—a common scenario in multi-compressor chiller plants. The result is a stable outlet water temperature within ±0.8°C of setpoint, which directly improves chiller COP (Coefficient of Performance) by 4–6%, translating to measurable kilowatt-hour savings for the end-user every operating day.
Parameter Specifications
|
Product |
Low Noise collecting Type Counterflow FRP Cooling Tower |
|||||||||
|
|
||||||||||
|
Model |
τ=27℃ |
Main Dimensions (mm) |
Air Volume m³/h |
Fan Diameter (mm) |
Motor Power (kw) |
weight (kg) |
inlet pressure 10⁴Pa |
noise at 10m dB (A) |
||
|
Total Height |
Maximum Diameter |
self-weight |
operating weight |
|||||||
|
DBNL3J-12 |
15 |
2333 |
1210 |
7200 |
700 |
0.6 |
217 |
775 |
1.96 |
40.3 |
|
DBNL3J-20 |
24 |
2423 |
1460 |
12400 |
800 |
0.8 |
244 |
958 |
2 |
41.1 |
|
DBNL3J-30 |
35 |
2642 |
1912 |
18000 |
1200 |
0.8 |
424 |
1734 |
2.21 |
43.5 |
|
DBNL3J-40 |
46 |
3142 |
1912 |
21500 |
1200 |
1.1 |
496 |
1896 |
2.6 |
43.5 |
|
DBNL3J-50 |
57 |
3130 |
2215 |
28000 |
1400 |
1.5 |
617 |
2505 |
2.65 |
44.7 |
|
DBNL3J-60 |
68 |
3430 |
2215 |
32300 |
1400 |
1.5 |
667 |
2829 |
2.78 |
45.7 |
|
DBNL3J-70 |
79 |
3444 |
2629 |
39200 |
1600 |
2.2 |
824 |
3816 |
3.03 |
47 |
|
DBNL3J-80 |
92 |
3744 |
2629 |
43400 |
1600 |
2.2 |
909 |
4240 |
2.86 |
47.5 |
|
DBNL3J-100 |
114 |
3694 |
3134 |
56000 |
1800 |
3 |
1014 |
5932 |
3.15 |
50 |
|
DBNL3J-125 |
142 |
3944 |
3134 |
67200 |
1800 |
4 |
1104 |
6158 |
3.15 |
50.7 |
|
DBNL3J-150 |
171 |
3953 |
3732 |
84000 |
2400 |
4 |
1744 |
8246 |
2.9 |
52 |
|
DBNL3J-175 |
200 |
4203 |
3732 |
94300 |
2400 |
5.5 |
1884 |
8582 |
3.15 |
53 |
|
DBNL3J-200 |
231 |
4235 |
4342 |
112000 |
2800 |
5.5 |
2208 |
11210 |
3.01 |
54.6 |
|
DBNL3J-250 |
283 |
4485 |
4342 |
134300 |
2800 |
7.5 |
2420 |
11983 |
3.26 |
55.6 |
|
DBNL3J-300 |
334 |
4623 |
5134 |
168000 |
3400 |
11 |
3648 |
17173 |
3.5 |
56.8 |
|
DBNL3J-350 |
395 |
4873 |
5134 |
187400 |
3800 |
11 |
3950 |
17850 |
3.75 |
57.3 |
|
DBNL3J-400 |
455 |
5018 |
6044 |
224000 |
3800 |
11 |
4406 |
23132 |
3.6 |
58.8 |
|
DBNL3J-450 |
514 |
5268 |
6044 |
242000 |
3800 |
11 |
4752 |
24510 |
3.85 |
58.8 |
|
DBNL3J-500 |
576 |
5619 |
6746 |
280000 |
4200 |
15 |
5887 |
30062 |
3.7 |
60 |
|
DBNL3J-600 |
680 |
6119 |
6746 |
302200 |
4200 |
18.5 |
6689 |
32164 |
4.2 |
61 |
|
Features |
The FRP cooling tower serves not only as a temperature regulator but also delivers an efficient, durable, and maintenance-free solution with optimized lifecycle costs. By harnessing the unique properties of FRP materials, it fundamentally addresses the critical challenges of corrosion and lifespan limitations in harsh operating environments, making it the go-to choice for cooling systems in modern industrial and commercial facilities. |
|||||||||
|
Application
|
Central air conditioning system: refrigeration station for commercial buildings, hotels and hospitals. |
|||||||||
|
Industrial refrigeration: process cooling for food processing, chemical, pharmaceutical and plastic industries. |
||||||||||
|
Power industry: auxiliary cooling system for thermal power plant and nuclear power plant. |
||||||||||
|
Manufacturing industry: circulating water cooling for metallurgical and mechanical processing plants. |
||||||||||
|
Data center: Provides cooling water for server rooms. |
||||||||||
|
Payment |
T/T, Western Union. |
|||||||||
|
Service |
Customize and design the size and style according to requirements |
|||||||||
Contact us immediately to discuss your product project requirements
Navigation
Navigation
Contact Us
Tel.: +86 189 3266 2725
E-mail: sale@hbfortis.com
Add.: No.8-1, Zhenxing Street, Matun Town, Zaoqiang County, Hengshui City, Hebei Province
Get in Touch
Get in Touch